– – 3 PS22 I/O check, sensor check PFTDB CN16-6 (ON) X-6 4 M23 operation check PFTDB CN14-3 to 4 X-9 5 Change M23 – – 6 Change PFTDB – – 7 Change PRCBĭescription:Tray 4 feeder up/down abnormality – – 2 Check the connector of M23 for proper drive coupling and correct as necessary. Remedy:1 Check the M23 connector for proper connection and correct as necessary. The tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.Ĭauses:Tray 3 upper limit sensor (PS22) Tray 3 lift-up motor (M23) Paper feed/transport drive board (PFTDB) Printer control board (PRCB). – – 3 PS14 I/O check, sensor check PFTDB CN10-10 (ON) Q-4 4 M8 operation check PFTDB CN22-9 to 10 X-4 5 Change M8 – – 6 Change PFTDB – – 7 Change PRCBĭescription:Tray 3 feeder up/down abnormality – – 2 Check the connector of M8 for proper drive coupling and correct as necessary. Remedy:1 Check the M8 connector for proper connection and correct as necessary. The tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.Ĭauses:Tray 2 upper limit sensor (PS14) Tray 2 lift-up motor (M8) Paper feed/transport drive board (PFTDB) Printer control board (PRCB).– – 3 PS6 I/O check, sensor check PFTDB CN11-3 (ON) Q-1 4 M6 operation check PFTDB CN23-9 to 10 X-3 5 Change M6 – – 6 Change PFTDB – – 7 Change PRCBĭescription:Tray 2 feeder up/down abnormality – – 2 Check the connector of M6 for proper drive coupling and correct as necessary. Remedy:1 Check the M6 connector for proper connection and correct as necessary. The tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.Ĭauses:Tray 1 upper limit sensor (PS6) Tray 1 lift-up motor (M6) Paper feed/transport drive board (PFTDB) Printer control board (PRCB).The lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.ĭescription:Tray 1 feeder up/down abnormality.– – 3 M25 operation check PFTDB CN13-6 (LOCK) X-11 4 Change M25 – – 5 PFTDB ICP6 conduction check – – 6 Change PFTDB – – 7 Change PRCBĭescription:Tray 3/4 feeder transportation motor turning at abnormal timing – – 2 Check the connector of M25 for proper drive coupling and correct as necessary. Remedy:1 Check the M25 connector for proper connection and correct as necessary.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
December 2022
Categories |